Lantronix Provisioning Manager XXE enables unauthenticated RCE
Free public brief. The indicators, the detections with Splunk SPL already written (plus Elastic and KQL where they apply), and a Slack alert the next time this touches a vendor you run are in the app — free account, no card.
XXE vulnerability in Lantronix Provisioning Manager versions 7.10.2 and prior allows unauthenticated remote code execution via malicious configuration files.
Lantronix Provisioning Manager versions 7.10.2 and earlier contain an XML External Entity (XXE) injection vulnerability (CVE-2025-7766) that allows unauthenticated attackers to execute arbitrary code on systems running the affected software. The vulnerability exists in the handling of configuration files supplied by network devices and requires low attack complexity but user interaction to trigger. With a CVSS v4 score of 8.6, this is a serious flaw affecting the IT sector worldwide.
Attackers can exploit this by crafting malicious XML configuration files that trigger XXE processing, potentially leading to remote code execution. No public exploitation has been reported at the time of this advisory. Lantronix has released version 7.10.4 or later as the fix. Defenders should prioritize updating affected Provisioning Manager instances immediately and implement network segmentation to limit exposure of ICS and IT infrastructure to untrusted sources.
Mentioned in this report
Detection guidance
Lantronix Provisioning Manager Process Spawning Shell or Script Interpreter (Windows)
Lantronix Provisioning Manager (Java-based) spawning cmd, PowerShell or LOLBin interpreters, consistent with post-exploitation of the XXE-to-RCE flaw CVE-2025-7766. Auto-generated starting point — validate and tune in your environment before deploying. IOC matches can false-positive on shared infrastructure and decay as adversary infrastructure rotates.
title: Lantronix Provisioning Manager Process Spawning Shell or Script Interpreter
(Windows)
description: Detects a process belonging to Lantronix Provisioning Manager spawning
a command interpreter or common download/execution utility. This is expected after
successful exploitation of the XXE to RCE flaw CVE-2025-7766, because the server
component should not launch interactive shells.
tags:
- attack.execution
- attack.t1059
- attack.initial-access
- attack.t1190
logsource:
category: process_creation
product: windows
detection:
selection_parent:
- ParentImage|contains: lantronix
- ParentCommandLine|contains: lantronix
selection_child:
Image|endswith:
- \cmd.exe
- \powershell.exe
- \pwsh.exe
- \wscript.exe
- \cscript.exe
- \mshta.exe
- \certutil.exe
- \bitsadmin.exe
condition: selection_parent and selection_child
falsepositives:
- Vendor installer or upgrade scripts launching cmd.exe from the Provisioning Manager
service during patching
- Administrators running documented maintenance batch files through the application
level: high
id: f5a1926b-5007-53f2-a8e7-11c306211cc6
status: experimental
author: Vorant
references:
- https://www.cisa.gov/news-events/ics-advisories/icsa-25-203-02
Lantronix Provisioning Manager Process Spawning Shell or Downloader (Linux)
Lantronix Provisioning Manager Java process spawning a shell, downloader or scripting runtime on Linux, indicating possible exploitation of CVE-2025-7766. Auto-generated starting point — validate and tune in your environment before deploying. IOC matches can false-positive on shared infrastructure and decay as adversary infrastructure rotates.
title: Lantronix Provisioning Manager Process Spawning Shell or Downloader (Linux)
description: Detects a Lantronix Provisioning Manager process spawning a shell, downloader
or scripting runtime on Linux. This is consistent with remote code execution after
XXE exploitation (CVE-2025-7766).
tags:
- attack.execution
- attack.t1059
- attack.initial-access
- attack.t1190
logsource:
category: process_creation
product: linux
detection:
selection_parent:
- ParentImage|contains: lantronix
- ParentCommandLine|contains: lantronix
selection_child:
Image|endswith:
- /sh
- /bash
- /dash
- /curl
- /wget
- /nc
- /ncat
- /python
- /python3
- /perl
condition: selection_parent and selection_child
falsepositives:
- Vendor start-up or upgrade shell scripts invoked by the application service
- Application health-check scripts that call curl or sh
level: high
id: 1d76956e-a523-5673-918c-56d11bdad007
status: experimental
author: Vorant
references:
- https://www.cisa.gov/news-events/ics-advisories/icsa-25-203-02
Behavioural rules are generated from public reporting — validate in your environment before deploying.
Source reporting: https://www.cisa.gov/news-events/ics-advisories/icsa-25-203-02
What this brief leaves out
This page is the free tier: the write-up, the severity, the names. In the app the same report carries its extracted indicators, its detections (Splunk SPL already written, plus Elastic and Microsoft KQL where they apply), the actors and CVEs it names as live profiles, and the vendor research on the same campaign — the primary source the news paraphrased, cited and read directly.
It sits in a corpus of 13,854 reports from 146 sources, 616 of them written in the last seven days, and it grows through the day.