# Siemens Mendix Studio Pro MCP Server flaws patched

Published: 2026-11-17 · Severity: routine · Sectors: Manufacturing, Energy
Canonical: https://vorant.io/reports/80adafcc-3bf1-5914-b912-989b6e251020/siemens-mendix-studio-pro-mcp-server-flaws-patched
Vorant's rating weighs the evidence in the report: confirmed exploitation, victims claimed, CVSS and EPSS, and how many sources agree. It rates the report, not your assets.

> Two vulnerabilities in Siemens Mendix Studio Pro's MCP Server could let attackers reach the server remotely or abuse CSRF for data access or system compromise.

Source: cisa.gov — https://www.cisa.gov/news-events/ics-advisories/icsa-26-321-05

## What to check

- Applies to: The 2 CVEs named below. Whether you run an affected version is not assessed: check the versions the source lists.
- Exploitation: No exploitation in the wild and no public exploit is recorded for the CVEs named.

Siemens disclosed two vulnerabilities affecting Mendix Studio Pro 11 (versions >=11.15.0 &lt;11.16.0 and the 11.12 branch >=11.12.6 &lt;11.12.7). The flaws reside in the MCP Server component: an unrestricted IP address binding issue (CWE Binding to an Unrestricted IP Address) that could allow an attacker with network access to interact with the server remotely, and a Cross-Site Request Forgery (CSRF) vulnerability that could trick a user's browser into sending unauthorized requests. Combined, these issues could lead to unauthorized data access, unauthorized tool execution, or broader system compromise. The advisory carries a CVSS v3 base score of 8.8.

Siemens has released updated versions of Mendix Studio Pro that address both vulnerabilities and recommends affected organizations update immediately. No evidence of in-the-wild exploitation is noted in this advisory. The affected product is used across critical manufacturing and energy sectors worldwide, with deployments globally; Siemens is headquartered in Germany.

This is a republished Siemens ProductCERT advisory (SSA-710379) via CISA. Standard ICS mitigations apply: minimize network exposure of control system devices, avoid direct internet accessibility, isolate control system networks behind firewalls separate from business networks, and use VPNs with up-to-date patching for any required remote access. Organizations should prioritize patching the MCP Server component and review for any unauthorized network interactions or CSRF-related activity against Mendix Studio Pro instances.

## Mentioned in this report

- Vulnerabilities: CVE-2026-112136, CVE-2026-112137

Source reporting: https://www.cisa.gov/news-events/ics-advisories/icsa-26-321-05

---

This is the free public brief from Vorant Threat Intelligence. When citing, attribute "Vorant" and link https://vorant.io/reports/80adafcc-3bf1-5914-b912-989b6e251020/siemens-mendix-studio-pro-mcp-server-flaws-patched.
In the app the same report carries live profiles of the CVEs it names. A free account in the app opens every report of the last 30 days, the security research and news included; the paid plans add the archive, what to hunt, the investigations and the rules as SIEM queries. Slack alerts on the vendors, sectors and countries a reader follows come with the paid plans too. A new account starts with a five-day trial, no card: https://vorant.io/signup